Barely Significant
← all excerpts

Peridynamics-Based Finite Element Analysis of Sealing Failure at Casing-Cement Sheath Interfaces in Ultra-Deep Wells.

ACS Omega · 2026 · PMC12854503 · PMID 41626470

1
hedged sentence
closest p
boldest claim

The sentences

an increasing trendno p-value reported
The contact is more prone to relative slip and cracking when tangential displacement reaches its maximum at 0° and 180°, when normal constraint is weakest and frictional resistance is low. The interface is heavily squeezed at 90° because of the greater horizontal primary stress resulting in the smallest tangential displacement. The total tangential displacement exhibits an increasing trend as the cement sheath elastic modulus rises.

also in 63,971 other papers

Quoted from the open-access full text in Europe PMC under the licence the publisher applied. The sentence is reproduced exactly as published; the emphasis is ours.