A comparative assessment of radiochemical purity and yield of [<sup>18</sup>F]PSMA-1007 production using two different automated synthesis platforms: a head-to-head comparison.

EJNMMI Radiopharm Chem · 2026 · PMC12913835 · PMID 41579247

1
hedged sentence
closest p
boldest claim

The sentences

In fact, the data derived from TLC analysis show comparable results (NEPTIS ® vs FASTlab2 TLC: 0.61 ± 0.37 vs 0.62 ± 0.53; p -value 0.468, Table 3 ), while the HPLC analyses showed a tendency to a superior purity with the FASTlab2 platform with a p- value very near to statistical significance (NEPTIS ® vs FASTlab2 HPLC: 95.86 ± 0.79%; HPLC 96.58 ± 1.25%; p -value 0.054, Table 3 ).