at the beginning of induction of MCAO had highly significant smaller infarct volumes at 48h after reperfusion than mice treated with vehicle (PBS) only or isotype control antibody (direct infarct volumes [mean±SD] : isotype control 177.4 ± 58.3 mm 3 , PBS 155.2 ± 50.4 mm 3 , TLR4mAb 86.3 ± 37.4 mm 3 ; p [PBS vs TLR4mAb] 0.0015, p [iso vs TLR4mAb] 0.0034) ( Fig 3A ).
← all excerpts
Evaluation of the Therapeutic Potential of Anti-TLR4-Antibody MTS510 in Experimental Stroke and Significance of Different Routes of Application.