The final release profiles were found to be little changed in 20–28% coating weight and 40–60% relative humidity range unlike film-controlled pellets which were almost significantly changed in 9–11% coating weight and 50–60% relative humidity, demonstrating TSH-SR pellets were more stable in the coating process.