In the present study, the complication rate in the silicone ring tourniquet group was lower than that in the pneumatic tourniquet group, although the difference did not reach statistical significance ( P = 0.059).
← all excerpts
The effect of silicone ring tourniquet in anterior cruciate ligament reconstruction: a retrospective comparative study.
1
0.0590
0.0590