After installing the auxiliary magnetic pole under the workpiece, the magnetic field gradient of the whole grinding area changes in a clear trend, and the magnetic abrasive renewal is more active during MAF processing, which significantly improves the utilization rate of the abrasive.
← all excerpts
Parametric Studies on Finishing of AZ31B Magnesium Alloy with Al<sub>2</sub>O<sub>3</sub> Magnetic Abrasives Prepared by Combining Plasma Molten Metal Powder with Sprayed Abrasive Powder.
2
—
—
The sentences
Checking the F-test (F-test) critical value table, the standard F-value for the given significance level at the significant level α = 0.05 is 2.534, and the F-value of the regression model of surface roughness is 22.53 > F 0.05 (14,12) = 2.424, indicating that the prediction model of the regression equation established between surface roughness and the four independent variables was highly significant, indicating a high degree of confidence in this prediction model.