Clinical Outcomes After Mitral Valve Replacement With Epic and Mosaic Bioprosthetic Valves.

Ann Thorac Surg Short Rep · 2024 · PMC11708627 · PMID 39790141

4
hedged sentences
0.0670
closest p · 1.3× alpha
0.1000
boldest claim

The sentences

just failed to reach statistical significanceP = .067so close (0.05 < p ≤ 0.1)
On multivariable analysis, the type of implanted mitral valve prosthesis just failed to reach statistical significance (HR, 0.43; 95% CI, 0.18-1.06; P = .067; Supplemental Table 3 ).

also in 35 other papers

failed to reach statistical significanceP = .10so close (0.05 < p ≤ 0.1)
On inverse probability of treatment weighted analysis, the difference in freedom from reintervention failed to reach statistical significance (HR, 0.46; 95% CI, 0.17-1.21; P = .10).

also in 1,120 other papers

an evident trendno p-value reported
At 10 years, the estimated freedom from reintervention rates were 62.2% (95% CI, 42.8%-84.5%) and 79.1% (95%, CI 62.1%-100%) for the Epic and Mosaic groups, respectively, with no statistically significant differences between groups ( P = .10; Figure 2 ), but an evident trend was observed.

also in 72 other papers

showed a trendno p-value reported
On multivariable analysis, the Epic group showed a trend of higher risk of reintervention, but the difference between groups just failed to reach statistical significance.

also in 13,339 other papers