However, we cannot confirm the superiority of ADP over TRAP for low platelet counts in FC as our ED 50 - and ED ref results suggest a slight trend towards the opposite.
← all excerpts
Assay validity of point-of-care platelet function tests in thrombocytopenic blood samples.
3
—
—
The sentences
In both FC and IA, ADP showed a tendency to require higher platelet count than TRAP for accurate results, although this trend did not reach statistical significance.
Stimulation with TRAP displayed a trend towards reaching the thresholds in both ED 50 (21 x10 9 /L) and ED ref (25 x10 9 /L) at lower platelet counts compared to stimulation with ADP (25 x10 9 /L each) but failed to reach statistical significance ( Figure 3 ).