An overall trend of the cyclohexane migration tests was that the weight loss results were much higher than those obtained in aqueous media (water or PBS), which is easily understood considering the essentially hydrophobic nature of both plasticizers and cyclohexane.
Though the tensile strength and yield strength of the 4 test steels all show a decreasing trend with the increase of cooling rate ( Figure 9 a,b), the decreasing rates of S3 and S4 are significantly lower than that of S1 and S2.
The difference of two absolute value equal or less than 20 is considered to be insignificant (marked as ≈) with 20 to 50 generally significant (marked as >) and more than 50 be highly significant (marked as »).
From Table 3 , shear stress change rate of MRG-50 is almost constant along with the magnetic field strength, while that of MRG-70 shows a decreasing trend.
From Table 5 , the loop area of MRG-70 shows an increasing trend as the shear rate increase from 0.005/s to 0.1/s, and this increasing trend decreases rapidly with the increase of external magnetic field strength, i.e., when the external magnetic field strength is zero, the shear rate-induced effect of MRG 70 is as high as 73%.
Overall, there is a clear trend of decreasing carbon with increasing input V/III ratio; however, data are spread out along the carbon concentration axis because of differences in GE for the three growth conditions (A, B, C).
The diffusion coefficients measured using ARICS show a decreasing trend with increasing particle size ( Figure 6 ), as expected based on the Stokes-Einstein equation.
A general feature of semiconductors consists in the occurrence of two different regions in the trend of the absolute value of the Seebeck coefficient versus the temperature, namely an increasing and a decreasing trend at low and high temperatures, respectively, separated by a maximum [ 42 ].
This was accompanied by a clear trend to define a set of criteria for performing meaningful mesocosm experiments with improved comparability of the results.
Different values of tensile stresses applied during annealing have resulted in a redistribution of magnetoelastic anisotropy showing a decreasing trend in both DW velocities and coercivity of nanocrystalline samples.
Through the observation and analysis of Figure 7 , with the increase of the corrosion ratio, the bond failure load of the specimens presents a decreasing trend.
Recent studies also show an increasing trend towards discrete-dislocation-dynamics-based phase field models [ 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 ] to describe plastic deformation, but such models can only be applied to smaller systems due to the associated computational cost.
The authors concluded that the use of biomaterials in the alveoli appeared to be slightly significant, especially when they were used in aesthetic areas [ 25 ].
They found that the contributions of volume to bulk modulus varied between 17.1% and 62.4%, which are quite significant and important in quantitatively describing the Cauchy ratio for the considered metals.